Environmentally Responsible Cooling - Evaporative Cooling Energy Saving and Safety Features

Use of a variable speed axial fan allows the cooler to operate using the minimum amount of electricity, ramping up and down only as required
Coolers operate using only 240v electricity the same amount of electricity as using 11/2 bars of an electric fire – No 3 phase power supply required.
Up to 35Kw of cooling from just 1.5Kw of electricity
Water Saving
Minimise the water requirement by the use of a unique level probe system which prevents overfilling.
Sophisticated control system provides alarms if there is a leak or fault in the system – this prevents a cooler leaking water for days before being noticed.
Unique scale control device allows accurate measurement of build up of solids allowing water to be drained away only when necessary.
Drain down
of system

Energy Saving

No harmful refrigerants are used just the natural process of evaporation to provide the cooling.
(See how evap cooling works)
Unlike air conditioning evaporative cooling uses clean fresh air, allowing odours and bacteria to be expelled naturally through the ventilation system without being re-circulated.
When Evaporative cooling is used as part of a balanced ventilation system to cool a building, this allows the exterior air to be used most of the time, making the most use of free cooling when available, therefore minimising costs and using natural resources.
EcoCooling are committed to providing cooling in the most cost effective, efficient manner using the traditional method of evaporative cooling but enhancing and building on the technology available to provide the best evaporative cooling systems in the world.
Unique Water Control System

A unique water control system is used in the cooler to maximise efficiency by the control of scale build up to prevent unnecessary water wastage and the build up of bacteria - A patented 4 probe water level system measures the water at 4 levels to ensure that water is drained completely away when the sump empties to ensure no build up of bacteria and a top level probe prevents overfill of the system and hence water wastage. The 2 middle probes control the inflow and outflow of water.
The system can be set for varying levels of water ph ensuring that scale build up is kept to a minimum and water is brought in only when required. The system re-circulates water until the salt build up is sufficient for the sump to be completely drained and new water brought in.
Low risk of Legionalla
NO water droplets .... NO water above 20°C in the system ... NO stagnant water
There has been NO KNOWN case of Legionnaires disease in an evaporative cooler and there are over 20 MILLION coolers installed in the western world.
A full Legionnela risk assessment on the ECP range is available on request
(click here for more detailed information on legionnaires disease)
ECOCOOLERS ARE NOW BEING USED IN HOSPITALS
Insect Protection
Removable Fly screens incorporated into the side panels are supplied as standard to protect the pads and provide basic hygiene - a must for food factories and other clean environments.

Control Box
UK Health and Safety Legislation
EcoCoolers conform with all UK & European health and safety regulations
Maintenance
EcoCoolers should be maintained twice a year