Telephone: 01284 810586

Evaporative Cooling from ecocooling

FORTHCOMING EVENTS:
We regularly attend trade shows and environmental events - any forthcoming events will appear below - we look forward to meeting you there

talk to Ecocoling about environmentally friendly evaporative cooling

 


ECOBUILD EXHIBITION
London, Earls Court
Stand 2103
2nd-4th March 2010

BEST PRACTICE LOW CARBON INNOVATION FORUM

National Motorcycle Museum
10th March 2010

NEMEX 2010
part of Sustainability Live
NEC Birmingham
20-22 April, 2010
Stand N29

Low Carbon Best Practice Exchange
10 June 2010
Olympia Conference Centre, London

THE ENERGY EVENT 2010
National Motorcycle Museum - Stand 54
8th-9th September 2010

ENERGY SOLUTIONS EXPO
London, Olympia
Stand F80
6th-7th October2010

 

Alan Beresford
MANAGING DIRECTOR OF ECOCOOLING
is on the CIBSE steering committee for the design of data centre Cooling

Case Studies - Cooling the Laundry

Evaporative cooling in factories
Evaporative Cooling in the laundry for Guarantee

Guarantee Laundries Limited is a UK based company providing rental garments and laundry service to all industrial sectors. In the main finishing department at its factory in Corsham its employees were experiencing uncomfortable conditions due to high temperature not untypical of most laundries. Guarantee had used mobile evaporative coolers but were seeking a more permanent solution.

A single side discharge EcoCooling ECP16000 evaporative cooler is installed feeding a ducted air distribution system.

A side discharge system was specified for simplicity of installation and maintenance. The main building has a fragile asbestos roof with all of the associated health and safety problems.

The unit is mounted on a simple framework sitting on the flat roof of an adjacent building.

Manual controls are inside the main factory building giving five air speeds and the option of cooling or pure ventilation modes.

laundry cooling with evaporative cooling from ecocooling

evaporative cooling - cooling laundries with Guarantee

A galvanised duct takes the air from the cooler to the heart of the factory building. The duct is insulated to maintain the low temperature of the cooled air and to prevent condensation.

The sizing of the system is based on the principle of air changes per hour. In a laundry it is normal to ventilate at a rate of 35 air changes per hour. In this case this is applied to spot cooling of individual work stations.

guarantee laundry - laundry cooling with evaporative cooling from ecocooling

Individual grills were fitted adjacent to each work station or area. These can be adjusted to give the required flow rate, direction and degree of diffusion required for the specific location.

In a laundry environment operator comfort is improved by providing ventilation, lower temperature air and air movement. On a typical hot day in the UK the ambient air temperature is reduced from 300C to under 220C using an EcoCooling evaporative cooler.