savings calculator

Computer Room Evaporative Cooling (CREC) Calculator

Adjust the editable figures below to best meet your requirements and click Calculate to assess the number of Evaporative Cooling Units you would need and the approximate savings you would make as compared to a conventional Refrigeration based system.

SERVER ROOM REQUIREMENTS
Cooling Demand kW Enter the total IT load
Δt through Server C A typical 1U server has a ΔT of 10C, blade servers go up to 15C. This is used to calculate the total flow of air. Normally use 10C
Mass flow rate Kg/s 2.5 Kg/s  
Air Flow Rate 2.1 m3/s  
 
Refrigeration
EcoCooling
 
Coefficient of performance
23.8
The Coefficient of Performance (COP) of computer room equipment varies. The very best CRAC's with full free cooling options and variable speed fans operate at a COP of ~3.7. In reality most 'good' systems achieve a COP of ~2.0. Many sites put as much energy into their cooling systems as they put into their IT equipment meaning the true COP is 1.0.
Fridge Electricity Use
12.5
0 kW
 
EcoCooler Fan Power
kW/m3/s
An EcoCooler produces 3m³/s of air using 1.5kW of electicity
True Coefficient of performance
2.0
23.8
 
Total Electricity Usage
12.5
1.1 kW
 
 
100%
8.1%
 
Annual Usage
 
Annual Running Hours
24hrs x 365 days
 
Refrigeration
Ecocooling
SAVINGS
Electricity Consumption
109500
9198
 
Electricity Cost
p/kWhr
 
Total Operating Cost
£10,950
£919.1
£10,030.1
Carbon Dioxide Impact
58.1
4.1
53.1 tonnes
  0.53702 kg/kWhr Carbon Dioxide UK value
   

      

RESULTS

Savings
Cost
Carbon
Annual
£10,030.1
53.1 tonnes
5 Year
£50,151
269.1 tonnes

EcoCoolers      
Flow Rate m3/hr This is dependent upon the EcoCooler type and the ductwork or air distribution resistance.
Number Required 0.8  
Design Number Required 1  Evaporative Cooling Unit 
Redundancy This is the design redundancy or resilience required of the system.
Net Requirements 2  Evaporative Cooling Unit   Evaporative Cooling Unit 

 

 

 

 

 

 

Site Design: Wyehead Design 2008